v. 1.2.1.473 29.01.2015 - Compatible with any from 1.2.1.468 and UP.

  • Changes in response to the Main Pump Controller reset.

v. 1.2.1.472 17.12.2014 - Compatible with any from 1.2.1.468 and UP.

 

  • The scale of the thrust PSI gauge is fixed.
  • The mud flow scale is set to gal/min. The 30 maximum value for gal/min.
  • The flow rates on the drill profile screen is in gal/min.

v. 1.2.1.471 04.12.2014 - Compatible with any from 1.2.1.468 and UP

  • Thrust gauge
    • The PSI scale changed to maximum 4500, the red area only when the psi is above 4000 while green when it’s below 4000.
    • The linear units changed to inch/min in the inner gauge.
  • Rotation gauge
    • Installed in the imperial system of measurement. 
  • MUD gauge
    • The Hydro Fracture Tracking meter is removed.
    • The mud flow rate changed to gallon/min.
  • Removed the button of “SETTINGS”.

v. 1.2.1.470 11.11.2014 - Compatible with any from 1.2.1.468 and UP

  • Fixed the User /Administrator access control issue;
  • Fixed Administration PIN
  • Joystick setup - unavailable
  • Engine Screen modifications (no Battery an Hydro Oil info)

v. 1.2.1.468 18.10.2014 - NO backward compatibilityOnly the drills with Main controller firmware release after 18 Oct. 2014 can use this software.

  • Improved drill status messaging;
  • Support of RPM adjustment;
  • ...
  • Elimination of visual defects and improve the perception of graphical information;

 


v. 1.2.1.464 18.09.2014 - Compatible with any from 1.2.1.461 and UP

  • Improved function - Detection of having internet connection;
  • The setup of the default network connections for drill computer;
  • ...
  • Elimination of visual defects and improve the perception of graphical information;

v. 1.2.1.463 17.09.2014 - Compatible with  any from 1.2.1.461 and UP.

  • E-Stop screen - More details about E-stop events;
  • Auto Screen function - on/off possibility in the Interface Setup;
  • Mud Pump - Changes in the functions of the control and information display;
  • Implementation of Pressure Washer operational display ;
  • Implementation of Devices Status Alert function;
  • Drill Profile - Empowering the controllers settings;
  • Engine display - The management of the Engine Run timing and the correctness of data display - no demo data;
  • Full control of the Network connections; 
  • Internet wide remote access;
  • Bringing the Computer display control to common principles; 
  • Additional characteristics on the diagnosis panels;

v. 1.2.1.461 11.09.2014 - NO backward compatibilityOnly the drills assembled after 01 Sept. 2014 can use this software.


v. 1.1.2.456 27.08.2014 - Demo version - For PC use only. Do not use this files on a Drill Computer. Download.

  • Adapting the interface control to work with the mouse;
  • WiFi Server is Disabled;
  • Replacement of incompatible functions;

v. 1.1.1.454 25.07.2014 - First release. Compatibility of this version is limited.  Only the drills assembled before 01 Sept. 2014 can use this software.